Work Procedure
ADDITIONAL SERVICE WHEN REPLACING TCM
Work Procedure
CAUTION:
When replacing TCM together with transaxle assembly, perform "ADDITIONAL SERVICE WHEN
REPLACING TRANSAXLE ASSEMBLY". Refer to "Work Procedure" .
1. SAVE THE TCM DATA
NOTE:
Save necessary data stored in TCM in CONSULT according to the following instructions:
1.Turn ignition switch OFF and wait for 10 seconds.
2.Turn ignition switch ON.
3.Select "Work Support" in "TRANSMISSION".
4.Select "READ IP CHARA - REPLACEMENT TCM".
5.Import data according to the instructions on the CONSULT screen.
- GO TO 2.
2. REPLACE THE TCM
1.Turn ignition switch OFF and wait for 10 seconds.
2.Replace the TCM. Refer to "Removal and Installation" Removal And Installation.
- GO TO 3.
3. WRITE THE TCM DATA
NOTE:
Write data saved in CONSULT into a new TCM according to the following instructions:
1.Turn ignition switch OFF and wait for 10 seconds.
2.Turn ignition switch ON.
3.Select "Work Support" in "TRANSMISSION".
4.Select "WRITE IP CHARA - REPLACEMENT TCM".
5.Write data saved in CONSULT in TCM according to the instructions on the CONSULT screen.
- WORK END