Without Intelligent Key System
P1610 LOCK MODE
Description
When the starting operation is carried more than five times consecutively under the following conditions, NATS
will shift to the mode which prevents the engine from being started.
- Unregistered mechanical key is used.
- BCM or ECM's malfunctioning.
DTC Logic
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1. PERFORM DTC CONFIRMATION PROCEDURE
1.Turn ignition switch ON.
2.Check "Self diagnostic result" with CONSULT.
Is DTC detected?
YES- Refer to "Diagnosis Procedure" .
NO- Inspection End.
Diagnosis Procedure
1. CHECK ENGINE START FUNCTION
1.Perform the check for DTC except DTC P1610.
2.Use CONSULT to erase DTC after fixing.
3.Check that engine can start with registered mechanical key.
Does the engine start?
YES- Inspection End.
NO- GO TO 2
2. CHECK INTERMITTENT INCIDENT
Refer to "Intermittent Incident" Intermittent Incident.
- Inspection End.