Removal And Installation
AIR CLEANER AND AIR DUCT
Removal and Installation
REMOVAL
NOTE:
Mass air flow sensor is removable as an assembly with the air cleaner cover.
1.Remove air duct (inlet) from the air cleaner body.
2.Disconnect PCV hose from the air duct.
3.Remove the air duct (between air cleaner case and electric throttle control actuator).
- Add matching marks if necessary for easier installation.
4.Remove air cleaner assembly with the following steps:
a.Disconnect the harness connector from mass air flow sensor.
b.Remove the two air cleaner body bolts.
c.Pull up on the air cleaner assembly to disengage it from the grommet and remove the air cleaner assembly.
CAUTION:
- Do not shock the mass air flow sensor.
- Do not disassemble the mass air flow sensor.
- Do not touch the sensor of the mass air flow sensor.
INSPECTION AFTER REMOVAL
Inspect air duct (inlet) and air duct for cracks, tears, or breaks.
Replace air duct (inlet) and air duct if any problems are found.
INSTALLATION
Installation is in the reverse order of removal.
NOTE:
Align marks, attach each joint and screw clamps firmly.