SRS Final Check
DIAGNOSIS SYSTEM (AIR BAG)
SRS Final Check
DIAGNOSIS MODE
1.Connect CONSULT.
2.Confirm that zero point reset of OCS is complete.
3.If no DTCs are detected on "SELF-DIAG RESULTS [CURRENT]", repair of SRS is completed. Go to step
4.
If any DTCs are detected on "SELF-DIAG RESULTS [CURRENT]", the malfunction has not been repaired completely or another malfunction is being detected. Perform SRS Operation Check again. Refer to SRC13, "SRS Operation Check".
4.Touch "ERASE".
NOTE:
Touching "ERASE" will clear the SRS memory of the malfunction ("SELF-DIAG [PAST]"). If "SELF-DIAG [PAST]" is not erased, User Mode may show the previous system malfunction even if the malfunction has been repaired completely.
5.Check that no malfunction is detected in "SELF-DIAG [PAST]".
6.Exit Diagnosis Mode and disconnect the CONSULT.
7.Perform SRS Operation Check. Refer to "SRS Operation Check" SRS Operation Check.