Operation CHARM: Car repair manuals for everyone.

Normal Operating Condition




NORMAL OPERATING CONDITION

Description


FRONT WIPER PROTECTION FUNCTION

IPDM E/R detects front wiper stop position by a front wiper stop position signal.
When a front wiper stop position signal is in the conditions listed below, IPDM E/R stops power supply to wiper after repeating a front wiper 10 seconds activation and 20 seconds stop.





NOTE:
This operation status can be confirmed on the IPDM E/R "Data Monitor" that displays "BLOCK" for the item
"WIP PROT" while the wiper is stopped.