PSD Reinitialization Procedure
To Reinitialize the Power Sliding Door (PSD) Controller:1. Turn the ignition switch to the "OFF" position.
2. PWR DOOR ON/OFF switch in the "OFF" position, located at Overhead (O/H) Console.
3. Make sure the Sliding Door is in the fully closed and latched position and unlocked.
4. Remove the TAIL fuse, from the Fuse Block.
5. Keep the TAIL fuse out for 30 seconds.
6. Reinstall the TAIL fuse.
7. Wait 10 seconds.
8. PWR DOOR ON/OFF switch moved to the "ON" position.
9. Cycle the PSD fully open until door stops, using either PWR DOOR switch on the RH "B" pillar or O/H Console.
10. Wait 5 seconds and cycle PSD fully closed.
11. Wait 5 seconds and repeat step 9.
^ If the door doesn't rest in the fully open position, repeat step 9 again.
12. Wait 5 seconds and cycle PSD fully closed.
13. Check Power Sliding Door for proper function.