Operation CHARM: Car repair manuals for everyone.

HVAC System - Automatic

REMOVAL PROCEDURE




1. Disconnect the pigtail harness connectors (1, 2) from the blower motor.




2. Disconnect the electrical connector (4) from the blower motor control processor (2).
3. Remove the blower motor control processor mounting screws (1).
4. Remove the blower motor control processor (2) from the blower case.

INSTALLATION PROCEDURE




1. Install the blower motor control processor (2) to the blower case.

NOTE: Refer to Fastener Notice in Service Precautions.

2. Install the blower motor control processor mounting screws (1).

Tighten
Tighten the screws to 1.9 N.m (17 lb in).

3. Connect the electrical connector (4) to the blower motor control processor (2).




4. Connect the pigtail harness connectors (1 and 2) to the blower motor.