Instrument Panel Cluster (IPC) - Replacement
Instrument Cluster Replacement
Removal Procedure
Important: The ignition switch must be in the OFF position when removing the instrument panel cluster.
1. Remove the IP cluster trim plate. Refer to Instrument Cluster Trim Panel Replacement (Instrument Cluster Trim Panel Replacement) .
2. Remove the screws from the IP cluster to instrument panel.
3. Remove the IP cluster from the instrument panel.
4. Disconnect the electrical connectors.
Installation Procedure
1. Connect the electrical connectors.
2. Position the IP cluster to the instrument panel.
Notice: Refer to Fastener Notice in Cautions and Notices.
3. Install the screws to instrument panel cluster.
Tighten the screws to 2.5 N.m (22 lb in).
4. Install the instrument cluster trim plate. Refer to Instrument Cluster Trim Panel Replacement (Instrument Cluster Trim Panel Replacement) .
When installing a new IP cluster it must be synchronized to the supplemental inflatable restraint (SIR) module in order to synchronize the new cluster. Refer to Instrument Cluster Programming/Synchronization and to Electronic Compass Calibration Service and Repair