Blower Motor Switch: Service and Repair
BLOWER MOTOR SWITCH REPLACEMENT - AUXILIARYREMOVAL PROCEDURE
1. Remove the IP trim plate.
2. Remove the auxiliary blower motor switch retaining screws.
3. Pull straight out from the IP in order to remove the auxiliary blower motor switch.
4. Disconnect the electrical connectors from the blower motor switch.
INSTALLATION PROCEDURE
1. Connect the electrical connectors to the blower motor switch.
2. Push in on the blower motor switch in order to install the blower motor switch.
NOTE: Refer to Fastener Notice in Service Precautions.
3. Install the auxiliary blower motor switch retaining screws.
Tighten
Tighten the screws to 2.5 N.m (22 lb in).
4. Install the IP trim plate.