General Information
DEPLOYMENT PROCEDURESThe inflator module can be deployed inside or outside of the vehicle. The method used depends upon the final disposition of the vehicle. Review each procedure in order to determine which will work best in a given situation.
DUAL STAGE INFLATOR MODULE
Dual stage inflator modules have 2 deployment stages. If stage 1 was used to deploy a dual stage inflator module, stage 2 may still be active. Therefore, a deployed inflator module must still be treated as an active inflator module. If disposal of a deployed or undeployed dual stage module is required, both deployment loops must be energized to deploy the inflator module.
SCRAPPING PROCEDURE
During the course of a vehicle's useful life, certain situations may arise which will require the disposal of a undeployed inflator module. Do not dispose a undeployed inflator module through normal disposal channels until the inflator module has been deployed. If scrapping a deployed dual stage inflator module, both stages must be energized. The following information covers the proper procedures for the disposing of a undeployed inflator module.
UNDEPLOYED INFLATOR MODULE
Take special care when handling or storing a undeployed or live inflator module. An inflator module deployment produces a rapid generation of gas. This may cause the inflator module, or an object in front of the inflator module, to project through the air in the event of an unlikely deployment.