Radiator Cooling Fan Control Module: Service and Repair
REMOVAL
1. Partially drain radiator.
2. Electrical connector from low coolant module.
3. Low coolant module.
^ To unlock low coolant module, lift one leg of the snap clip from its locked position and pull outward with a slight twisting motion.
^ Inspect condition of O-ring seal.
INSTALLATION
1. O-ring.
^ Lubricate O-ring seal with coolant.
2. Place snap clip leg in place.
3. Low coolant module.
4. Electrical connector to low coolant module.
5. Fill radiator.
NOTE: To properly fill the system requires the use of the air bleed vents.
6. Finally inspect for leaks.