Operation CHARM: Car repair manuals for everyone.

Recirulation Door

RECIRCULATION DOOR REPLACEMENT

REMOVAL PROCEDURE
1. Remove the IP carrier.
2. Open the HVAC passenger compartment air filter access door.
3. Remove the HVAC passenger compartment air filters.
4. Disconnect the recirculation actuator electrical connector.







5. Remove the top air inlet housing retaining screws.
6. Remove the side air inlet housing retaining screws.
7. Remove the air inlet housing from the HVAC module assembly.








8. Remove the screws retaining the air inlet housing halves.
9. Separate the air inlet housing halves.







10. Remove the recirculation door from the air inlet housing.




INSTALLATION PROCEDURE







1. Install the recirculation door to the air inlet housing.







2. Align the recirculation door with the other half of the air inlet housing.
3. Connect the air inlet housing halves.
4. Install the screws retaining the air inlet housing halves.

NOTE: Refer to Fastener Notice in Service Precautions.
Vehicle Damage Warnings

Tighten
Tighten the screws to.....0.9 N.m (8 lb in).







5. Install the air inlet housing to the HVAC module assembly.
6. Install the air inlet housing screws.

Tighten
Tighten the screws to.....0.9 N.m (8 lb in).

7. Connect the recirculation actuator electrical connector.
8. Install the HVAC passenger compartment air filters.
9. Close the HVAC passenger compartment air filter access door.
10. Install the IP carrier.