Secondary (Dual Zone)
Secondary Mode Door Replacement (Dual Zone)
Removal Procedure
1. Remove the heater core cover.
2. Remove the right hand air temperature actuator.
3. Remove the right hand air temperature mounting bracket screws.
4. Remove the right hand air temperature mounting bracket.
5. Disconnect and remove the right hand mode door lever from the mode door.
6. Disconnect and remove the secondary mode door lever from the secondary mode door.
7. Remove the secondary mode door from the HVAC module.
Installation Procedure
1. Install the secondary mode door.
2. Connect the secondary mode door lever to the secondary mode door.
Important: Align the pin on the right hand mode door lever with the slot on the secondary mode door lever.
3. Connect the right hand mode door lever to the mode door.
4. Install the right hand air temperature mounting bracket.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
5. Install the right hand air temperature mounting bracket screws.
Tighten
Tighten the screws to 0.9 Nm (8 lb in).
6. Install the right hand air temperature actuator.
7. Install the heater core cover.