Operation CHARM: Car repair manuals for everyone.

Auxiliary (With LH Power Sliding Door [RPO E59] )





Auxiliary Blower Motor Replacement (with E59)

Removal Procedure






1. Remove the left lower quarter trim panel.
2. Disconnect the auxiliary blower motor electrical connector.
3. Disconnect the auxiliary blower motor resistor electrical connector.
4. Remove the lower auxiliary air distribution duct bolts and retainers.
5. Remove the lower auxiliary air distribution duct.

Important: The auxiliary blower motor must be removed with the blower motor housing.

6. Remove the auxiliary blower motor housing screws.






7. Lift the auxiliary blower motor housing and remove from the HVAC module assembly.






8. Remove the auxiliary blower motor mounting screws.
9. Remove the auxiliary blower motor from the blower motor housing.

Installation Procedure






1. Install the auxiliary blower motor to the blower motor housing.

Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

2. Install the auxiliary blower motor mounting screws.

Tighten
Tighten the screws to 1.6 Nm (14 lb in).






3. Install the blower motor housing to the auxiliary HVAC module assembly.
Align the rear tabs of the blower motor housing to the HVAC module.
4. Install the auxiliary blower motor housing screws.

Tighten
Tighten the screws to 1.6 Nm (14 lb in).






5. Install the lower auxiliary air distribution duct.
6. Install the lower auxiliary air distribution retainers.
7. Install the lower auxiliary air distribution ducts bolts.

Tighten
Tighten the bolts to 10 Nm (89 lb in).

8. Connect the auxiliary blower motor resistor electrical connector.
9. Connect the auxiliary blower motor electrical connector.
10. Install the left lower quarter trim panel.