Sliding Door Rear Lock Replacement
Sliding Door Rear Lock Replacement
Removal Procedure
Important: By removing the power sliding door (PSD) 15A fuse, the low current logic power for both the LH and RH power sliding door modules (PSDM) will be interrupted and both PSDs will be inoperative.
1. If equipped with a power sliding door, disable the PSD system by removing the PSD 15A fuse from the instrument panel (I/P) fuse block.
2. Remove the sliding door inner trim panel.
3. Remove the sliding door water deflector.
4. Remove the sliding door latch screws.
5. When the sliding door rear lock is loose, unhook the lock rod from the sliding door rear lock.
6. Disconnect the detent switch electrical connector.
7. Remove the sliding door rear lock from inside the sliding door.
Installation Procedure
1. Position the sliding door rear lock inside the sliding door.
2. Hook and secure the lock rod to the sliding door rear lock.
3. Connect the detent switch electrical connector.
Notice: refer to Fastener Notice.
4. Install the sliding door rear lock screws according to the specified fastener tightening sequence.
Tighten the screws, in sequence as shown, to 10 N.m (89 lb in).
5. Verify the operation of the lock assembly. Adjust, if needed.
6. Install the sliding door water deflector.
7. Install the sliding door inner trim panel.
Important: By installing the 15A fuse, the low current logic power will be restored to both the LH and RH PSDMs and the PSDs will be operational. However, both PSDMs will have to learn the full open and full closed positions of the PSD.
8. If equipped with a power sliding door, enable the PSD system by installing the PSD 15A fuse into the I/P fuse block.