Heated Oxygen Sensor 1 Replacement
HEATED OXYGEN SENSOR 1 REPLACEMENT
REMOVAL PROCEDURE
1. Disconnect the HO2S 1 harness connector.
2. Remove the HO2S 1 from the exhaust manifold.
INSTALLATION PROCEDURE
1. NOTE: Silicone based products will contaminate the HO2S. Use only a nickel based anti-seize compound that does not contain silicone.
Apply a small amount of anti-seize compound to the threads of the HO2S 2.
2. NOTE: Refer to Component Fastener Tightening Notice.
Install the HO2S 1 to the exhaust manifold.
Tighten the HO2S 1 to 42 N.m (31 lb ft).
3. Connect the HO2S 1 harness connector. Push in the connector until a click is heard and pull back to confirm a positive engagement.