Generator Replacement (LNJ)
Generator Replacement (LNJ)
Removal Procedure
1. Disconnect the negative battery cable.
2. Remove the drive belt.
3. Disconnect the engine wiring harness electrical connector (1) from the generator.
4. Reposition the engine wiring harness boot (4).
5. Remove the generator terminal nut (2).
6. Remove the engine wiring harness terminal lead (3) from the generator.
7. Remove the generator bolts (1).
8. Remove the generator (2).
Installation Procedure
1. Install the generator (2).
Notice: Refer to Fastener Notice.
2. Install the generator bolts (1).
Tighten the bolts to 50 N.m (37 lb ft).
3. Install the engine wiring harness terminal lead (3) to the generator.
4. Install the generator terminal nut (2).
Tighten the nut to 20 N.m (15 lb ft).
5. Position the engine wiring harness boot (4).
6. Connect the engine wiring harness electrical connector (1) to the generator.
7. Install the drive belt.
8. Install the negative battery cable.