Service Procedure
1. Disconnect negative battery cable.
2. Drain coolant (save in clean container for reuse) to a level just below TVS.
3. Remove air cleaner.
4. Remove canister purge TVS (see Illustration).
5. Coat new canister purge TVS (P/N 10055876) with thread sealant and install.
6. Reinstall air cleaner.
7. Refill coolant.
8. Reconnect negative battery cable.