A/C Accumulator Protector
FIGURE 1:
Install:
1. Cut a total of 7 mm from center of plastic ring as shown in Figure 1.
FIGURE 2:
2. Remove 2 hex head screws and upper insulation cover.
3. Pull accumulator up and remove "well nuts."
4. Insert divided plastic ring around the insulation-lower, accumulator without disconnecting freon lines.
5. Insert "well nuts."
6. Install upper insulation cover.
7. Install accumulator bracket using 2 hex head screws.