Shifts 1-3 (Misses 2nd)
1. Intermediate servo sticking, leaking or damaged.
2. Stuck or unseated accumulator exhaust check valve.
3. 1-2 valve sticking in control valve pump assembly.
4. Wrong or incorrectly installed spacer plate or gasket.
5. Governor feed passage to 1-2 valve blocked.
6. Intermediate band apply feed orifice blocked.
7. Case or case cover intermediate servo apply passage blocked.