Refrigerant Pressure Sensor / Switch: Service and Repair
A/C System Switch Locations:
TIP: The pressure cycling switch is mounted on a Schrader-type valve. It is not necessary to recover the refrigerant from the A/C system to replace this switch.
REMOVE OR DISCONNECT
1. Electrical connection from switch.
2. Switch and O-ring seal.
INSTALL OR CONNECT
1. Switch and new O-ring seal.
2. Tighten Switch to 5 Nm (44 lb. in.).