Test D: Blower Motor Does Not Turn Off
BLOWER MOTOR DOES NOT TURN OFF1. Disconnect the Blower Switch connector.
^ If the Blower Motor stops, replace the Blower Switch.
^ If the Blower Motor continues to run, go to step 2.
2. Disconnect the Blower Resistors connector.
^ If the Blower Motor stops check the YEL (51) and LT BLU (72) wires for a short to battery voltage.
^ If the Blower Motor continues to run check the ORN (52) wires for a short to battery voltage.