Oxygen Sensor: Service and Repair
Oxygen Sensor:
The following procedure should be performed with engine temperature over 120° F otherwise the oxygen sensor may be difficult to remove.
1. Disconnect battery ground cable.
2. Disconnect oxygen sensor electrical connector, then carefully loosen oxygen sensor and remove.
NOTE: Replacement oxygen sensors should have a special anti-seize compound applied to threads. If replacement sensor is lacking anti-seize compound or original sensor is to be re-installed, coat threads with suitable anti-seize compound.
3. Reverse procedure to install. Torque oxygen sensor to specification.
Torque Value: 38-46 N-m (28-33 lb.ft.)