Chart G: Air Flows Out Wrong Outlets

Chart G: Air Flows Out Wrong Outlets:




Air Delivery Manual (C61) (Part 2):





Check operation of valves using the chart. Adjust Blower Speed to HI to give a strong air flow (engine warm and running at idle).

NOTE: The letters in the chart correspond to the valve positions shown in the diagram.

^ If tests indicate only one valve is not operating correctly, make the following checks:

- Air valve and vacuum actuator move freely.

- Vacuum hose is connected and not pinched.

- Vacuum is present when valve is moved from rest position. If vacuum is not present, replace A/C Mode Selector.

^ If no valves operate, check violet hose for vacuum at the Heater and A/C Control Assembly. If vacuum is not present, check hose back to engine vacuum source for pinching or leaks.