Dieseling/Run-On
DEFINITIONEngine continues to run after key is turned "OFF"
PRELIMINARY CHECKS
- Perform the careful visual / physical checks as described in Preliminary Checks.
FUEL SYSTEM
- Check the ignition switch and switch adjustment.
- Check for short to B+ on CKT 3, CKT 39, CKT 139, CKT 339, CKT 239, CKT 439, CKT 539, CKT 639 or CKT 739.