Troubleshooting Hints
PERFORM BEFORE BEGINNING SYSTEM DIAGNOSIS1. Check HVAC Fuse 6 for open. If open, check for short to ground in CKT 241.
2. Check Fusible Link A.
3. Check that G201 and G200 are clean and tight. Check for a broken (or partially broken) wire inside of the insulation which could cause system malfunction but prove "GOOD" in a continuity/voltage check with a system disconnected. These circuits may be intermittent or resistive when loaded, and if possible, should be checked by monitoring for a voltage drop with the system operational (under load).
^ Check for proper installation of aftermarket electronic equipment which may affect the integrity of other systems (refer to "Troubleshooting Procedures"). Diagnostic Aids
^ Refer to System Diagnosis.