Operation CHARM: Car repair manuals for everyone.

Turn Lamps

With the Ignition Switch in the "ON" or "START" positions, voltage flows from the BACK Fuse through the normally closed contacts of the Hazard Switch to the Turn/Hazard Flasher. The Turn/Hazard Flasher is grounded through the Junction Block at G203. The Turn/Hazard Flasher contains a solid state timer/relay. When the Turn Signal Switch is in the LH or RH Turn position, the solid state timer/relay receives a ground signal through the LH or RH Turn Lamps. When the timer/relay receives this signal, voltage flows through the Turn/Hazard Flasher and the Turn Signal Switch to the LH or RH Front and Rear turn Lamps and LH or RH Turn Indicator. The LH and RH Front and Rear Turn Lamps are all permanently grounded. Depending on Turn Signal Switch position (LH or RH turn position), the LH or RH Turn Lamps and LH or RH Turn Indicator will flash approximately 80-90 times per minute.