Manifold Pressure/Vacuum Sensor: Service and Repair
MAP Sensor Service:
REMOVAL PROCEDURE
1. Disconnect the MAP sensor electrical connector.
2. Remove the MAP sensor attaching screws.
INSTALLATION PROCEDURE
1. Install the MAP sensor attaching screw.
Tighten
Screw to 2-4 Nm (18-35 lb in).
2. Connect the MAP sensor electrical connector.