Fuel Tank Pressure Sensor: Service and Repair
Fuel Tank Pressure Sensor:
REMOVAL PROCEDURE
1. Disconnect the negative battery cable.
2. Perform Fuel Pressure Relief Procedure.
3. Drain fuel tank.
4. Remove the fuel tank. Refer to Fuel Tank.
5. Remove the electrical connector from the fuel tank vapor pressure sensor.
6. Remove the fuel tank vapor pressure sensor (1) from modular fuel sender.
INSTALLATION PROCEDURE
1. Install the new fuel tank vapor pressure sensor (1) to modular fuel sender.
2. Install the electrical connector to fuel tank vapor pressure sensor.
3. Install the fuel tank.
4. Refill tank.
5. Install the negative battery cable.