Operation CHARM: Car repair manuals for everyone.

Blower Motor Switch: Service and Repair

Remove or Disconnect

1. Negative battery cable.
2. Instrument panel trim plate.
3. Blower switch knob.
4. Control assembly.
5. Electrical connection.
6. Blower switch retaining screws and blower switch.

Install or Connect

1. Blower switch and retaining screws.

Tighten
^ Screws, fully driven, seated and not stripped.

2. Electrical connection.
3. Blower switch knob.
4. Control assembly and retaining screws.

Tighten
^ Screws to 1 N.m (9 lb in).

5. Instrument panel trim plate.
6. Negative battery cable.

Tighten
^ Bolt to 16 N.m (12 lb ft).