Operation CHARM: Car repair manuals for everyone.

V5 - Conventional Mount




REMOVAL PROCEDURE

TOOLS REQUIRED
^ J 5403 Snap Ring Pliers
^ J 39500-B A/C Refrigerant Recovery, Recycling and Recharging (ACR4) System

1. Recover the refrigerant using the J 39500-B.
2. Remove the control valve retaining ring using the J 5403.
3. Remove the control valve assembly (5).

INSTALLATION PROCEDURE

TOOLS REQUIRED
J 5403 Snap Ring Pliers

1. Coat the O-ring with 525 viscosity refrigeration oil.
2. Using thumb pressure, push the O-ring in place.

IMPORTANT: Ensure that the retaining ring is properly seated in the ring groove.

3. Using the J5403, install the valve retaining ring (5) with the high point of the curved sides against the valve housing.
4. Evacuate the system. Recharge the system.
5. Perform a leak test. Refer to Compressor Leak Testing (V5-Conventional Mount). Service and Repair