HO2S Warm-Up Sensor 1 / HO2S Warm-Up Sensor 2
Scan Tool Range
00:00 to 99:99 MIN:SEC. Indicates time to warm-up for each
HO2S. The HO2S warm up time is used for the HO2S heater test. The
PCM will run the heater test only after a cold start (determined by engine coolant and intake air temperature at the time of startup) and only once during an ignition cycle. When the engine is started the PCM will monitor the HO2S voltage. When the HO2S voltage indicates a sufficiently active sensor, the PCM looks at how much time has elapsed since startup. If the PCM determines that too much time was required for the HO2S to become active, a DTC will set. If the engine was warm when started, HO2S Warm-Up will display the value that was stored last time the test ran. If info has been cleared, HO2S Warm-Up will display 00:00.