REMOVAL PROCEDURE
1. Turn OFF the ignition.
2. Remove the fuel injection sight shield.
3. Remove the 2 access cover retaining bolts (1) while holding down the access cover (2) of the crankcase ventilation valve.
4. Remove the access cover (2).
5. Remove the spring (3).
6. Remove the crankcase ventilation valve (4) and the O-ring (5).

INSTALLATION PROCEDURE
1. Install the crankcase ventilation valve (4) and the O-ring (5).
2. Install the spring (3).
3. Install the access cover (2).
4. Install the 2 access cover retaining bolts while holding down the access cover.
5. Reinstall the fuel injection sight shield.