MAF Input Frequency
The scan tool range is
0 to 32000 Hz. The mass air flow sensor input signal to the
PCM is a frequency which varies from around
3000 Hz at idle to above
7000 Hz at wide-open throttle. The PCM converts this frequency signal to grams per second to be displayed on the scan tool as
MAF.