Scan Tool Does Not Power Up
Diagnostic Chart:
CIRCUIT DESCRIPTION
The data link connector (DLC) provides operating power for the scan tool at terminal 16 (battery positive voltage) and at terminal 4 (ground). The DLC provides the class 2 serial data signal at terminal 2 and the signal ground at terminal.The scan tool will power up with the ignition off.
TEST DESCRIPTION
1. The CIG/ACCY fuse supplies power to the DLC terminal 16.
4. The DLC battery positive voltage and ground circuits are functioning properly. The malfunction must be due to the scan tool.