Right Defogger
REMOVAL PROCEDURE1. Remove the instrument panel (IP).
2. Remove the following components from the IP:
^ The 3 screws
^ The defroster nozzle (13)
^ The left side demister duct (16)
^ The right side demister ducts (4)
3. Remove the following components from the IP:
^ The 1 screw
^ The left side vent duct (15)
^ The right side vent duct (5)
^ The center vent duct (14)
4. Remove the left (15) and right (5) vent ducts from the center vent duct (14) (if necessary).
INSTALLATION PROCEDURE
1. Install the left and right vent ducts to the center vent duct (if necessary).
2. Install the following components to the IP:
^ The 1 screw
^ The left vent duct (15)
^ The right vent duct (5)
^ The center vent duct (14)
3. Install the following components to the IP:
^ The defroster nozzle (13). Secure the nozzle with the 3 screws.
^ The left demister duct (16)
^ The right demister ducts (4)
4. install the IP.