If the refrigerant oil was removed from the A/C system during the recovery process or during the component replacement, the refrigerant oil must be replenished. Add the refrigerant oil as indicated.Accumulator 105 ml
Compressor 60 ml
Condensor 30 ml
Evaporator 90 ml
NOTE: Replacement compressors do not have any oil in the compressor. Add the correct amount of oil to the replacement compressor before replacement.
NOTE: Remove the compressor crankcase drain bolt. Drain the oil from the compressor crankcase.
- If less than 30 ml (1 oz) is drained, add 60 ml (2 oz) to the new compressor.
- If more than 30 ml (1 oz) is drained, add the same amount that was drained to the new compressor.
- Up to 120 ml (4 fluid ounces) of oil may collect in the crankcase. When replacing a compressor, drain and measure the oil in the old compressor crankcase. Discard the old oil after recording the amount.