Turn Signal Flasher: Service and Repair
REMOVAL PROCEDURE
1. Remove the LH Instrument Panel (IP) insulator.
2. Remove the steering column filler panel.
3. Remove the hazard and turn signal flasher by slide it to the right to release the flasher tabs from the slots on the Body Control Module (BCM) bracket.
4. Disconnect the electrical connector from the hazard and turn signal flasher.
INSTALLATION PROCEDURE
1. Connect the electrical connector to the hazard and turn signal flasher.
2. Position the hazard and turn signal flasher to the (BCM) bracket, then slide the flasher to the left to secure the flasher tabs into the retaining slots on the bracket.
3. Install the steering column filler panel.
4. Install the LH IP insulator.