Window Switch Operation (4 Door)
Voltage is applied to the window switches when the ignition switch is in the ACCY or the RUN position. Voltage is applied to the window switches along the following path:1. Through the PWR WDO circuit breaker
2. To circuit 143
3. To the left front window switch
4. Through circuit 1307
5. To all of the switches
Voltage is applied to the right front window regulator motor through circuit 666 when you press the UP position on the right front window switch. The motor is grounded through the following areas:
^ Circuit 667
^ The DOWN contact in the right front window switch
^ Circuit 167
^ The DOWN contact in the left front window switch
The motor runs in order to drive up the window. Voltage is applied to the right front window regulator motor when you press the DOWN position of the right front window switch. Voltage is applied to the right front window regulator motor in the opposite direction through circuit 667. The motor is grounded through the following areas:
^ Circuit 666
^ The UP contact in the right front window switch
^ Circuit 166
^ The UP contact in the left front window switch
The motor runs in order to drive down the window. The other windows operate from their individual window switches in a similar manner.