Manifold Pressure/Vacuum Sensor: Service and Repair
REMOVAL PROCEDURE
1. Remove the air cleaner outlet resonator.
2. Disconnect the MAP sensor electrical connector.
3. Remove the MAP sensor attaching screws (1).
4. Remove the MAP sensor vacuum hose (2).
INSTALLATION PROCEDURE
1. Connect the vacuum hose (2).
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the MAP sensor attaching screw (1).
Tighten
Tighten the attaching screw to 6.5 N.m (5.7 lb in).
3. Connect the MAP sensor electrical connector.
4. Install the air cleaner outlet resonator.