Blower Motor: Service and Repair
BLOWER MOTOR AND FAN REPLACEMENTREMOVAL PROCEDURE
1. Remove the right Instrument Panel (IP) insulator.
2. Disconnect the electrical connections at the blower motor.
3. Remove the blower motor retaining screws.
4. Remove the blower motor and fan assembly.
INSTALLATION PROCEDURE
1. Install the blower motor and fan assembly.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the blower motor screws.
Tighten
Tighten the blower motor screws to 5 N.m (44 lb in).
3. Connect the blower motor electrical connector.
4. Install the right Instrument Panel (IP) insulator.