A/C REFRIGERANT PRESSURE SENSOR REPLACEMENTREMOVAL PROCEDURE
1. Disconnect the electrical connection at the sensor.
IMPORTANT: The sensor is mounted on a service fitting. Do not discharge the system.
2. Remove the pressure sensor. Discard the O-Ring seal.
INSTALLATION PROCEDURE
1. Lubricate the new O-Ring seal in clean 525 viscosity refrigerant oil.
2. Install the new O-Ring seal.
NOTE: Refer to Fastener Notice in Service Precautions.
3. Install the pressure sensor.
Tighten
Tighten the sensor to 5 N.m (44 lb in).
4. Connect the electrical connection at the sensor.