Oxygen Sensor Wiring Harness Heat Shield Replacement
Oxygen Sensor Wiring Harness Heat Shield ReplacementRemoval Procedure
Caution: Refer to Hot Exhaust System Caution in Service Precautions.
Caution: Refer to Exhaust Parts Removal Caution in Service Precautions.
1. Raise and support the vehicle. Refer to Vehicle Lifting.
Caution: Eye protection must be worn when drilling rivets to reduce the chance of personal injury.
2. Drill through the center of the heat shield rivets.
3. Remove the heat shield (2) from the floor panel.
4. Remove the oxygen sensor retainer (1) from the heat shield (2).
Installation Procedure
1. Install the oxygen sensor retainer (1) to the heat shield.
2. Position the heat shield (2) to the floor panel, aligning the holes.
3. Using a rivet gun, fasten both the oxygen sensor wiring harness heat shield (2) and the catalytic converter heat shield to the floor panel with a single rivet (3).
4. Install the remaining rivets.
5. Lower the vehicle.