AC Pressure Sensor
A/C REFRIGERANT PRESSURE SENSOR REPLACEMENTREMOVAL PROCEDURE
1. Disconnect the electrical connector from the A/C refrigerant pressure sensor.
2. Remove the A/C refrigerant pressure sensor and the seal.
3. Discard the seal.
INSTALLATION PROCEDURE
Coat the seal with a mineral base 525 viscosity refrigerant oil.
1. Install a new seal to the A/C refrigerant pressure sensor fitting.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the A/C refrigerant pressure sensor.
Tighten
Tighten the A/C refrigerant pressure sensor to 6 N.m (53 lb in).
3. Connect the electrical connector to the A/C refrigerant pressure sensor.