HVAC Control Assembly Replacement
REMOVAL PROCEDURE1. Remove the IP trim plate.
2. Remove the HVAC control assembly retaining screws.
3. Pull the HVAC control assembly (1) away from the IP.
4. Disconnect the electrical connections.
5. Disconnect the vacuum hoses.
6. Disconnect the temperature control cable.
INSTALLATION PROCEDURE
1. Connect the electrical connections.
2. Connect the temperature control cable.
3. Connect the vacuum hoses.
4. Install the HVAC control assembly (1) to the IP.
NOTE: Refer to Fastener Notice in Service Precautions.
5. Install the HVAC control assembly retaining screws.
Tighten
Tighten the screw to 2 N.m (18 lb in).
6. Install the IP trim plate.