Glove Compartment: Adjustments
Striker Adjustment - IP Compartment
Removal Procedure
1. Open the instrument panel (IP) compartment door.
2. Loosen the fasteners (2) securing the IP compartment striker (1) to the IP.
3. Adjust the IP compartment striker.
Installation Procedure
Notice: Refer to Fastener Notice in Service Precautions.
1. Tighten the fasteners (2) securing the instrument panel (IP) compartment striker (1).
Tighten the fasteners to 2 N.m (18 lb in).
2. Close the IP compartment door.