Operation CHARM: Car repair manuals for everyone.

Blower Motor: Service and Repair

BLOWER MOTOR REPLACEMENT

REMOVAL PROCEDURE




1. Remove the right instrument panel insulator.
2. Disconnect the blower motor electrical connector.
3. Remove the blower motor bolts (2).
4. Remove the blower motor (3).

INSTALLATION PROCEDURE




1. Install the blower motor (3). Guide the blower motor (3) into position.
Do not catch the blower motor fan on the protruding parts.

NOTE: Refer to Fastener Notice in Service Precautions.

2. Install the blower motor bolts (2).

Tighten
Tighten the blower motor bolts (2) to 2.3 N.m (20 lb in).

3. Connect the blower motor electrical connector.
4. Install the right instrument panel insulator.