Operation CHARM: Car repair manuals for everyone.

High Blower Speed

When the High blower speed is selected, the HVAC control assembly applies voltage to the blower motor relay through the high blower motor control circuit. The voltage energizes the blower motor relay, causing the blower motor to be connected to the battery positive voltage. Power and ground and supplied to the blower motor relay, internally in the underhood junction block. The blower motor is grounded through the ground circuit.