Fuel Gage Inaccurate or Inoperative
DIAGNOSTIC AIDS^ Ensure that the fuel level is in the same range as the customer concern.
^ For intermittent diagnosis, refer to Testing for Intermittent and Poor Connections in Diagnostic Aids
^ Refer to Fuel Level Specifications in order to verify the correct fuel level sensor readings. The Fuel Tank Level Remaining (%) parameter is available on the scan tool in the PCM EVAP Data list.
TEST DESCRIPTION
Steps 1-4:
Steps 5-13:
The number(s) below refer to the step number(s) on the diagnostic table.
3. This step tests for a high resistance in the signal circuit and the low reference circuit of the fuel level sensor.
13. DTCs will be set in the PCM when you perform this diagnostic table.