Blower Motor Switch: Service and Repair

REMOVAL PROCEDURE




1. Remove the HVAC control assembly.
2. Remove the blower switch knob.
3. Disconnect the blower switch electrical connector.




4. Remove the blower switch from the look tabs.
5. Remove the blower switch from the HVAC control assembly.

INSTALLATION PROCEDURE




1. Install the blower switch to the HVAC control assembly.




2. Install the blower switch knob. Connect the blower switch electrical connector.
3. Install the HVAC control assembly.